iPad CU-SPR HJARTARÆSINGARTÆKI - AED - GB,FR,IT,ES,DE,PL,US,KR tilgreina tungumál við pöntun (iPad CU-SPR DEFIBRILLATOR - AED - GB,FR,IT,ES,DE,PL,US,KR specify language with order)

GIMA35400

:
0 kr

Lýsing

Tækniskilgreiningar HJARTARÆSINGARTÆKI Rekstrarhamur: hálf-automatiska Bylgjuform: e-cube biphasic (skert veldisgerð) LCD/LED skjár: stöðu tækisins, rafhlöðustig og stöðu padanna Úttaksorku fyrir fullorðna: 200 J við 50 O álag Úttaksorku fyrir börn: 50 J við 50 O álag Hleðslustýring: stjórnað af sjálfvirku sjúklingagreiningarkerfi Hleðslutími: innan 3 sekúndna frá því að raddskipun, "Rafstraumur er nauðsynlegur" er gefin.


Tæknileg gögn

Tegund Medical device
Flokkur (CE) II B
EAN 8809435481161
CND Z12030501

📄 Hlaða niður gagnablaði (PDF)



Lýsing á ensku

Technical Specifications Defibrillator Operating mode: semi-automated Waveform: e-cube biphasic (Truncated exponential type) LCD/LED display: device status, battery level and pads status Output energy for adults: 200 J at 50 O load Output energy for children: 50 J at 50 O load Charge control: controlled by an automated patient analysis system Charging time: within 3 seconds from when the voice instruction, "An electric shock is needed" is issued Time from initiation of rhythm analysis: 12 seconds with a new battery (even after the delivery of 15 discharges at 200J) Time from power on to readiness for discharge: 25 seconds with a new-fully charged battery (even after the delivery of 15 discharges at maximum energy) Time from CPR to shock: at least 6 seconds from the end of CPR to shock delivery Disarm: - patient’s heart rhythm changes to non-shockable rhythm - SHOCK button is not pressed within 15 seconds Speaker: provides voice prompts Sound level: 80 ~ 90 dB (±3dB), apart 1m above speaker Beeper: provides various audible indications Automatic self test: "power On Self-Test, Run-time Self-Test Daily, Weekly, and Monthly Self-Test" Manual test: battery pack insertion test Battery type: 12V DC, 4.2 Ah LiMnO2, disposable Operating time: at least 150 shocks (200J) for a new battery or 6 hours of operating time Battery shelf life: at least 5 years from the date of manufacture Storage: internal memory: 5 individual treatments, up to 3 hours per treatment Size - weight: 240x230xh 70 mm - 2 kg ECG analysis system Impedance range: 25O to 175O Shockable rhythms: ventricular fibrillation or fast ventricular tachycardia Acquired ECG Lead: Lead II Frequency response: 1 Hz to 30 Hz

Tengdar vörur

Recently viewed